目录
本作品由 懒桔子2 精心制作
搜索
书签
PM-260 Instruction manual of ion fan

Model:PM-260MH

CONTENTS
01

Installation steps and use environment

02

Introduction of functions and parameters

03

Daily maintenance

04

Fault analysis

Operation instruction
1、Unpacking
Remove the styrofoam and erect the machine
Packing box
2、Power adapter
3、Connect power, standby

4、Handles used to move equipment

Installation steps and use environment

Installation steps and use environment

Ion wind(PM-260)[Model PM2.5] Instructions

Plug in 12V input power supply, the machine is in standby state.

Press the key once and enter the automatic control mode. When the particle PM2.5 drops to 25 or below, the machine only turns on the purification function, and when the particle rises to more than 28, automatically turn on the intake fan to accelerate the circulation.

Press the key twice,and the intake fan starts together with the purification function.

Press the key 3 times,only start the purification function, and the intake fan does not start.

Press the key 4 timesto stop, and standby.

PM-260MA Automatic

Press the function key to switch the machine.

Press the key once, level 1.

Press the key twice, level 2.

Press the key 3 times, level 3.

Press the key 4 times to stop, and standby.

PM-260MH Manual

Introduction of functions and parameters

Ion fan PM-260HH/A,PM-260MH/ATechnical parameters

一、Technical index

1、The machine includes active disinfection and passive disinfection, and has the dual functions of sterilization and decomposition of harmful gases. The disinfection and purification factor is ion.

2、The machine has a long service life, the core part of the ion generator is made of metal parts as a whole, there is no loss in use, and the maintenance cost in use is reduced.

3、The plasma produced by the ion generator is a kind of corona discharge plasma with high density.

4、Applicable volume: ≤100 m³,Applicable area:≤40㎡。

5、Noise:manual(No fan installed)≤20dB,Automatic(fan installed)≤45dB

6、Normal working environment: temperature range: 5℃ ~ 60℃, humidity: ≤ 90%

7、Working power supply: 12V 50Hz input power: manual type ≤ 15w; Automatic type ≤ 30w

8、The machine is of movable type. Overall dimensions: according to machine dimensions.

9、Machine size (mm): 260x380x1323

10、Dust collector size (mm): 978X130

11、Discharge rack size (mm): 1032X130

12、Net weight 12.6KG, gross weight 16.9KG

Functions and parameters

Functional index

Number

Fitting name

Model

Quantity

1

Movable shell

260L

1

2

Microcomputer controller

movable type

1

3

Dust collector

978X130mm

1

4

Discharge rack

1032X130mm

1

Packing list

Number

Fitting name

Quantity

1

Power adapter

1

2

Host machine

1

3

Instructions

1

4

Certificate

1

5

Warranty card

1

二、Functional index

1、The machine is green and environmentally friendly, has no damage to people and objects, no secondary pollution to the environment, and is suitable for human living environment.

2、The machine automatically gives an alarm when there is a fault, and the fly back transformer is protected automatically in the event of short circuit and abnormal discharge to prevent accidents.

3、The digital intelligent plasma high voltage generator has the functions of short circuit protection, precise adjustment and working status indication, which put an end to the potential danger of fire.

Functions and parameters

Special tip: first cut off the 12V input power, there is still a small amount of static electricity in the discharge rack, please do not touch the metal body of the discharge rack directly.

Take out the wire and discharge rack of the discharge rack, and do not pull or touch the wire with force or external objects (the wire will be broken by strong pull or collision).

Daily maintenance

Daily maintenance

Cleaning method:Clean the wire with a slightly wet or dry cloth, wipe along the wire traction direction, remove the oxide on the metal surface (do not push outward or inward), and be careful not to put it on the surface with spikes when placing the wire rack, which is easy to be broken.Clean the unit every 7days.

Use soap or alcohol to clean surface particle appendages and nicotine, wipe dry after cleaning.

Discharge rack placement program:First put in the dust collection discharge rack, and then put in the wire discharge rack.

The back door has a door switch, the door is open, the switch is off, and the door switch is in normal contact.

Install the reference picture correctly.

Daily maintenance

Daily maintenance

Reconnect the power supply and press the function switch to start at once.

Fault analysis

Fault analysis

1. Whether the discharge rack is out of order.


2. Whether the power cord falls off.


3. Whether the movable door is installed in place.


4. If there is no above situation, please call the company for advice.